Seite 1 - Solo E1 DSU User

Solo E1 DSU User Guide Part 098-00917-01 Rev. CJune 1998

Seite 2

x Solo E1 DSU User Guide—June 1998

Seite 3 - ISO Compliance

5-10 Solo E1 DSU User Guide—June 19985Pattern TestsTable 5-2 contains a list of these pattern tests.The QRW TestQRW (Quasi Random Word) is a pseudo ra

Seite 4

Diagnostics 5-115The Send 1:4 (or alternate) TestUse when the loopup remote test fails to put the remote system into loopback. You can determine if th

Seite 5 - Table of Contents

5-12 Solo E1 DSU User Guide—June 19985Status LEDsUse the LEDs to verify the test progress (Table 5-5).Running Tests From Front Panel From the front pa

Seite 6 - Chapter 3, ConÞguration 3-1

Diagnostics 5-135DTE/NET LoopbackTo start this test:1. Press DTE/LPBK to start the DTE/NET loopback test.2. Press DTE/LPBK again to end the test.Loopu

Seite 7 - Chapter 4, Maintenance 4-1

5-14 Solo E1 DSU User Guide—June 19985The pattern tests are listed in Table 5-7.Table 5-7 Pattern Tests Pattern Test DescriptionSend All Ones Use thi

Seite 8 - Chapter 5, Diagnostics 5-1

6-16Troubleshooting 6This chapter describes problems you may encounter and possible solutions (see Table 6-1 on page 6-2). If these solutions do not c

Seite 9 - Table of Contents ix

6-2 Solo E1 DSU User Guide—June 19986The Solo E1 DSU Does Not Power UpIf the unit is AC powered, make sure the Solo E1 DSU is plugged into a live AC o

Seite 10

Troubleshooting 6-36Make sure Connection is set to Modem and two valid telephone numbers are set in Phone Number 1 and Phone Number 2 in Menu 8 Alarm

Seite 11 - List of Figures

6-4 Solo E1 DSU User Guide—June 19986If the Solo E1 DSU still does not loopup, use your E1 test set to inject a fractional loopback signal into the pa

Seite 12

Troubleshooting 6-56If the yellow alarm is disabled, this condition is ignored. In the alarm menu, indicate ÒRAIÓ for Network status. The CTS line on

Seite 13 - List of Figures xiii

xi List of Figures Figure 1-1 The Solo E-1 DSU 1-1 Figure 1-2 Typical Multi-point Frame Relay Network App. 1-2 Figure 2-1 Solo E1 DSU Tray and

Seite 14

6-6 Solo E1 DSU User Guide—June 19986The DATA Port RTS/CTS LEDs do not IlluminateIf the DTE device does not support the RTS or DTR signalling, set the

Seite 15 - List of Tables

A-1ATechnical SpeciÞcations AThis appendix lists information on both the module and standalone products.Table A-1 Network InterfaceItem RatingTransmit

Seite 16

A-2 Solo E1 DSU User Guide—June 1998ARegulatory Applicable European harmonized standards:¥ 89/336/EEC¥ 92/31/EEC¥ 93/68/EEC¥ 73/23/EECTable A-3 Power

Seite 17 - List of Tables xvii

Technical Specifications A-3A¥ 98/13/ECTo maintain EMC Class B (CE Label) compliance, shielded cables should be used with the unit. Table A-6 Mechanica

Seite 18

A-4 Solo E1 DSU User Guide—June 1998ADiagnosticsThe unit is designed to facilitate the maintenance of the line and troubleshooting of problems by inco

Seite 19 - Organization

Technical Specifications A-5ARelated Model NumbersTable A-10 lists the model numbers of related Digital Link products.Table A-10 Digital Link Equipment

Seite 20 - Conventions

A-6 Solo E1 DSU User Guide—June 1998ADL1081 DE-9 to DE-9, 2 connectionsCommunications Cables Cable to terminalDL1082 DE-9 to DE-9, 4 connectionsDL1083

Seite 21 - Typography

B-1BConnector and Pin AssignmentsBTable B-1 lists the pin assignments for the DA15 network interface connector.Table B-2 describes DATA port signals

Seite 22 - Send Us Your Comments

B-2 Solo E1 DSU User Guide—June 1998BTable B-3 describes DATA port signal from the equipment to the DSU.Clear To Send CTS(D)CTS-A, B(5,13)CS-A, B(9,

Seite 23 - Preface xxiii

Connector and Pin Assignments B-3BTable B-4 describes DATA port signals.Signal Ground SG(B) SG(7) SG(19)Frame Ground A 11DTE side connection only.1.

Seite 24

xii Solo E1 DSU User Guide—June 1998 Figure 3-5 Menu-6 Timeslot ConÞg. in Default Mode 3-13 Figure 3-6 Menu-0 SNMP ConÞg. 3-16 Figure 3-7 Menu-

Seite 25 - Introduction 1

B-4 Solo E1 DSU User Guide—June 1998BTable B-5 describes the pin assignments for the DB-25 to RS-449 DATA port connector.Table B-5 DB-25 to RS-449 DA

Seite 26 - Service Features

Connector and Pin Assignments B-5BTable B-6 describes the pin assignments for the DB-25 to V.35 DCE connector.Table B-7 describes the DB-25 to RS-449

Seite 27 - Management Capabilities

B-6 Solo E1 DSU User Guide—June 1998BTable B-8 describes the communication port pin assignments.22 164324 146212 630 2229 2311 2025 107835 917 1719 7N

Seite 28

Connector and Pin Assignments B-7BTable B-9 lists the Communication Port parameter options.Table B-10 lists the pinout assignments for this adapter.1.

Seite 29 - Installation 2

B-8 Solo E1 DSU User Guide—June 1998B

Seite 30 - Cable Requirements

C-1CFactory Default ConÞgurationCTable C-1 Factory Default Configuration Item Default Item DefaultUnit Unit ID Unique ID assigned Protect Mode Disable

Seite 31 - Installing on a Flat Surface

C-2 Solo E1 DSU User Guide—June 1998CSNMP IP Address 0.0.0.0 IP Subnet Mask 0.0.0.01st NMS Address 0.0.0.0 2nd NMS Address 0.0.0.03rd NMS Address 0.0.

Seite 32 - Installing on a Tray

D-1DConÞguration Worksheet DPrint, Þll out, and keep this chart near the device.Table D-1 Configuration Worksheet Item Setting Item SettingUnit Unit I

Seite 33 - Installation 2-5

D-2 Solo E1 DSU User Guide—June 1998DBlock All Alarms Loss of Signal from data port Net Carrier Loss Alarm Net Sync Loss AlarmNet UA1 Received Alarm C

Seite 34 - DIP switches

E-1ESoftware Download EMenu-4A Download UtilityThe Download feature provides a quick method to upgrade the device Þrmware. The features are:¥ Separate

Seite 35 - DIP switches for S1 and S2

List of Figures xiii Figure 5-1 Menu-9 Diagnostics 5-2 Figure 5-2 Loop DTE TestÑFull and Fractional Bandwidth 5-6 Figure 5-3 Loop NET Test 5-7

Seite 36

E-2 Solo E1 DSU User Guide—June 1998E¥ Downloading code.Figure E-1 Menu-4 Main Config.—Flash DownloadSetting Up for TFTPThe procedures for local or rem

Seite 37 - Installation 2-9

Software Download E-3E3. Arrow down to the Forward Over IBC Þeld and make sure it is set to enabled.Now proceed to Menu-4 and follow the steps for T

Seite 38

E-4 Solo E1 DSU User Guide—June 1998EFigure E-3 Menu-4A Download Utility Setting Up for XMODEMTo download new software:1. Create a new directory on yo

Seite 39 - Grounding the Solo E1 DSU

Software Download E-5ETable E-1 describes the parameters of Figure E-3.Table E-1 Download Utilities GroupsGroup Field DescriptionCODE FILE 1 Version V

Seite 40 - Cable Connections

E-6 Solo E1 DSU User Guide—June 1998EThe menu and download options for the Download Utility are shown in Table E-2.Abnormal TerminationThe download pr

Seite 41 - Network BNCs

Software Download E-7EError IndicatorsIf the download utility or the operational software fails, an error indicator appears. Depending on the error in

Seite 42

E-8 Solo E1 DSU User Guide—June 1998EDownload Aborted by UserYou may abort the XMODEM downloading process by typing Ctrl-X.To perform the downloading

Seite 43 - Connect a Modem

I-1IIndex IAAC power supplytroubleshooting 6-2alarmstroubleshooting 6-2AMI E1 line code formattesting 5-10AMI E1 line code formattesting 5-14Bbaud rat

Seite 44 - DE-9 Connector, Pin 8

I-2 Solo E1 DSU User Guide—June 1998Itroubleshooting 6-5external alarms 3-22external timing B-2Ffractional E1troubleshooting loopback 6-3framingtroubl

Seite 45 - Installation 2-17

Index I-3IMenu-9 Diagnostics 5-14RRAI Received AlarmMenu-7 Alarm I 3-19redrawing screen 3-6RFC1406SNMP network management 1-1RS-232straight-through ri

Seite 46 - Installing the Module

xiv Solo E1 DSU User Guide—June 1998

Seite 47 - Installation 2-19

I-4 Solo E1 DSU User Guide—June 1998I

Seite 48 - Item Status Description

xvList of TablesTable 2-1 DIP Switch S2-12 Description 2-2Table 2-2 Solo E1 DSU Cabling Equipment Requirements 2-2Table 2-3 Solo E1 DSU Stan

Seite 49

xvi Solo E1 DSU User Guide—June 1998Table 3-4 Menu-5 Data Config. 3-11Table 3-5 Menu-0 SNMP Config. Parameters 3-16Table 3-6 Menu-7 Alarm I P

Seite 50

List of Tables xviiTable 5-7 Pattern Tests 5-14Table 6-1 Problem List 6-2Table A-1 Network Interface A-1Table A-2 Data Interface A-1Table A

Seite 51 - ConÞguration 3

xviii Solo E1 DSU User Guide—June 1998Table B-7 DB-25 to RS-449 DCE Connector Pin Assignments B-5Table B-8 Communication Port Pin Assignments B-6T

Seite 52 - Log On Through Telnet

xixPrefaceThe Solo E1 DSU User Guide provides the information you need to install, test, operate, and manage the Solo E1 DSU. AudienceThis guide is pr

Seite 53 - Access Rights

Copyright Copyright © 1998, Digital Link CorporationWorld copyright reserved. No part of this publication may be stored in a retrieval system, transm

Seite 54

xx Solo E1 DSU User Guide—June 1998Appendix E, ÒSoftware Download,Ó to upgrade Þrmware applications.ConventionsThis section describes the conventions

Seite 55 - Using The Terminal Interface

Preface xxiTypographyDigital Link manuals delineate the names of Þles, commands, and actions by using the fonts and typefaces described in the followi

Seite 56 - Setting a Parameter

xxii Solo E1 DSU User Guide—June 1998Digital Link Technical SupportIf you should experience difÞculty with the setup and/or operation of your Digital

Seite 57 - Configuration 3-7

Preface xxiiiIs the manual thorough?Is the manual easy to use: can you Þnd the information you need?Is anything missing from the manual? What would yo

Seite 58 - Setting Unit ID

xxiv Solo E1 DSU User Guide—June 1998

Seite 59 - Configuring Network Parameters

1-11Introduction 1Solo E1 FeaturesThe Solo E1 DSU (Data Service Unit) is a single data port DSU that enables access to high-speed public and private E

Seite 60

1-2 Solo E1 DSU User Guide—June 19981¥ The Solo E1 DSU connects high-speed bridges, routers and other data terminal equipment to the Internet and fram

Seite 61 - Configuring the DATA Port

Introduction 1-31¥ DTE or DCE interface and a DB-25 connector on the back¥ Bandwidth mapping into contiguous or manually selected 64 kbps slots¥ Selec

Seite 62 - Allocating Timeslots

1-4 Solo E1 DSU User Guide—June 19981

Seite 63 - to choose

2-12Installation 2This chapter describes installing the Solo E1 DSU Standalone and module:¥ ÒPre-Installation ChecksÓ on page 2-1 (apply to both the S

Seite 64

Digital Link shall not be liable for failure to perform its obligations if such results directly or indirectly from, or is contributed to by, any act

Seite 65 - Menu-0 SNMP Configuration

2-2 Solo E1 DSU User Guide—June 19982Terminal and DIP Switch ModeOn the rear of the standalone and/or the module board are two DIP switch banks. DIP s

Seite 66

Installation 2-32Table 2-3 list the power requirements for the Standalone Solo E1. The shelf meets all the power requirements for the module.Installin

Seite 67 - Menu-7 Alarm I Conditions

2-4 Solo E1 DSU User Guide—June 19982Installing on a TrayA tray can secure 2 Solo E1 DSUs. Rack-mounting requires a mounting tray.To mount the Solo E1

Seite 68

Installation 2-52Figure 2-1 Solo E1 DSU Tray and Rack MountSetting the DIP Switches on the Solo E1 DSU StandaloneThe S1 and S2 DIP switches are locate

Seite 69

2-6 Solo E1 DSU User Guide—June 19982DIP switch mode is the active mode by default (switch S2-12 is OFF). The default is all switches OFF (Figure 2-2)

Seite 70 - Figure 3-8 Menu-8 Alarm II

Installation 2-72Figure 2-3 S1 and S2 DIP Switch SettingsSolo E1 DSU instructions for DIP switch conÞgurations are located on the bottom of the unit (

Seite 71 - (Default) Setting Description

2-8 Solo E1 DSU User Guide—June 19982(Also refer to ÒBasic Parameters Using Menu-4 Main ConÞgurationÓ on page 3-7.)Connecting the Standalone to AC or

Seite 72

Installation 2-92Connecting Standalone to AC PowerTo connect the Solo E1 DSU to AC power:1. Insert the AC power cable into the power receptacle on the

Seite 73 - Configuration 3-23

2-10 Solo E1 DSU User Guide—June 199822. Connect the tray cable to the Solo E1 DSU DC power connector:a. Plug the colored wire to the positive (+) ter

Seite 74 - Modem Initialization Strings

Installation 2-112Figure 2-4 Preparing the DC Power Tray CableGrounding the Solo E1 DSUGround the Solo E1 DSU to earth ground using a grounding cable

Seite 75 - Configuration 3-25

Caution In accordance with FCC Part 15 section 15.21, changes or modiÞcations made by the buyer that are not expressly approved by Digital Link Corpo

Seite 76

2-12 Solo E1 DSU User Guide—June 19982A bare, covered or insulated grounding conductor is acceptable. A conductor that is individually covered or insu

Seite 77 - Maintenance 4

Installation 2-132Figure 2-5 Connecting to DATA, COMM, and NETNOTE: DA/B/E ports are 120 ohm and BNC ports are 75 ohmCOMM (refer to Table 2-8)NET (ref

Seite 78 - Menu-1 Main Status

2-14 Solo E1 DSU User Guide—June 19982Use DL1081, DL1082, and DL1083 to daisy-chain Solo E1 DSUs (refer to ÒConnecting Multiple Standalone Solo E1 DSU

Seite 79 - Unit Status

Installation 2-152Check the COMM Port Parameters Verify that the COMM port parameters on the Solo E1 DSU and terminal or modem match. The defaults ar

Seite 80 - Network Status

2-16 Solo E1 DSU User Guide—June 199823. Connect the remote terminal:a. Plug the phone line to the modem. b. Connect the modem to the remote terminal.

Seite 81 - Error Statistics

Installation 2-172Figure 2-6 Solo E1 DSUs Daisy-Chained to a TerminalInstalling The Solo E1 DSU ModuleRequest this information from your network admin

Seite 82 - DATA Status

2-18 Solo E1 DSU User Guide—June 19982Installing the ModuleTo install the module:1. Check the contents of the shipping carton.Check for visible damage

Seite 83 - Maintenance 4-7

Installation 2-192Use Table 2-9 and Table 2-10 to conÞgure the jumpers shown in Figure 2-7.Figure 2-7 Module Jumper SettingsTable 2-9 Ensemble Shelf D

Seite 84

2-20 Solo E1 DSU User Guide—June 19982Standalone And Module Front Panel LEDsThe LEDs on the Solo E1 DSU provide the status of the data port, network p

Seite 85 - Parameter Description

Installation 2-212RTS YellowOffRequest to send line (RTS) from DTE is asserted.RTS line removed, indicating unit is not sending valid data.CTS YellowO

Seite 86

v Table of Contents Audience xix Organization xix Conventions xx Symbols xx Typography xxi Digital Link Technical Support xxii Returning a Unit xxii

Seite 87 - Event Log

2-22 Solo E1 DSU User Guide—June 19982

Seite 88 - (Default) Events

3-13ConÞguration 3This chapter provides procedures to set up the Solo E1 DSU:¥ ÒLogging On and OffÓ on page 3-1¥ ÒAccess RightsÓ on page 3-3¥ ÒUsing T

Seite 89

3-2 Solo E1 DSU User Guide—June 19983Log On from a Terminal When you log on for the Þrst time, use the following steps:1. Press Ctrl-X, type the unit

Seite 90

Configuration 3-33Logging Off To log off, press Ctrl-X. When the terminal stops responding to your keystrokes, you are logged off.Access RightsThe Solo

Seite 91 - Diagnostics 5

3-4 Solo E1 DSU User Guide—June 19983The default value is an empty text string. No password is required to log on for the Þrst time. If you do not set

Seite 92 - Shortcut

Configuration 3-53SuperuserThe Superuser has the rights to access Solo E1 DSU at anytime. If a user is logged on through telnet and the Superuser logs

Seite 93 - Shortcut Test Options

3-6 Solo E1 DSU User Guide—June 19983To access a menu, enter the code (press one of the 0, 1, 2, 3, 4, 5, 6, 7, 8, or 9 keys) for that menu. Modify in

Seite 94 - Self Test

Configuration 3-735. Choose the desired option by pressing the Return key to select that option.6. If prompted to conÞrm your action, type y.If you ty

Seite 95 - Error Code Description

3-8 Solo E1 DSU User Guide—June 19983Figure 3-2 Menu-4 Main Config.Table 3-4 describes the parameters of Figure 3-2.Setting Unit ID1. Activate Terminal

Seite 96 - The Loop DTE Test

Configuration 3-933. Use the arrow keys to move to the ID Þeld.4. Press the Return key to start edit mode. The Þeld blinks and at the bottom of the scr

Seite 97 - The Loop Payload Test

vi Solo E1 DSU User Guide—June 1998 Cable Connections 2-12 Connecting a Terminal to the Standalone 2-14 Check the COMM Port Parameters 2-15 Connect t

Seite 98 - The DTE/NET Test

3-10 Solo E1 DSU User Guide—June 19983In-band bit must match on the local and remote units. The factory setting default is 4.If changing Frame or Inba

Seite 99 - The Loopup/Down Remote Tests

Configuration 3-113Configuring the DATA PortTo conÞgure the DATA port, select Menu-5 Data ConÞguration (Figure 3-4).Figure 3-4 Menu-5 Data Config.Table 3

Seite 100 - Pattern Tests

3-12 Solo E1 DSU User Guide—June 19983Allocating TimeslotsThe default factory network timeslot allocation for bandwidth is 31 DS0 timeslots allocated

Seite 101 - The Lamp Test

Configuration 3-133Figure 3-5 Menu-6 Timeslot Config. in Default ModeAllocating Contiguous Timeslots In this example, we allocate DATA port 1, slots 1 t

Seite 102 - Status LEDs

3-14 Solo E1 DSU User Guide—June 19983b. Press the enter key to activate edit mode.Type a port number (NN for a data port, I for Idle, or the UP or Do

Seite 103 - The Pattern Tests

Configuration 3-153a. Select Manual.Do you really want to change the configuration [Y/N]?b. Select y for yes.2. Allocate by timeslot:a. Press enter t

Seite 104 - Pattern Test Description

3-16 Solo E1 DSU User Guide—June 19983Figure 3-6 Menu-0 SNMP Config.Table 3-5 describes the parameters of Figure 3-6.Table 3-5 Menu-0 SNMP Config. Param

Seite 105 - Troubleshooting 6

Configuration 3-173Menu-7 Alarm I ConditionsAlarm conditions are categorized as network and DATA port alarm conditions. Alarm conditions affecting netw

Seite 106

3-18 Solo E1 DSU User Guide—June 19983DATA port alarm condition recognizes and reports the loss of DTE, by setting the Solo E1 DSU to recognize loss o

Seite 107 - Troubleshooting 6-3

Configuration 3-193Menu-8 Alarm II ConfigurationsWhen you choose Menu-8, the Solo E1 DSU standalone shows these sub-menu choices. The module version sho

Seite 108 - The NET LED is Constantly Red

Table of Contents vii Setting Date or Time 3-9 Configuring Network Parameters 3-9 Configuring the DATA Port 3-11 Allocating Timeslots 3-12 Allocation

Seite 109 - Troubleshooting 6-5

3-20 Solo E1 DSU User Guide—June 19983Figure 3-8 Menu-8 Alarm IIExternal Alarm Configuration (Module only)Use External Alarm ConÞguration to deÞne exte

Seite 110 - No LEDs Illuminate

Configuration 3-213Figure 3-9 Menu-8 Alarm II—Ext. Alarm Config.Table 3-7 describes the parameters of Figure 3-9.Table 3-7 Ext. Alarm Config. ParametersP

Seite 111 - Technical SpeciÞcations A

3-22 Solo E1 DSU User Guide—June 19983Miscellaneous Management ConfigurationUse Miscellaneous Management ConÞguration to deÞne external communications

Seite 112 - Regulatory

Configuration 3-233Table 3-8 describes the parameters of Figure 3-10.Table 3-8 Menu-8 Alarm II Parameters Parameter(Default) Settings DescriptionConne

Seite 113 - Technical Specifications A-3

3-24 Solo E1 DSU User Guide—June 19983Modem Initialization StringsTo initiate a modem connection, the Solo E1 DSU sends +++ followed by the Þrst modem

Seite 114 - Telnet and SNMP Management

Configuration 3-253Figure 3-11 Menu-8 Alarm II—Modem INIT StringsIf you use the modem reset command, set all parameters up to the reset command as the

Seite 115 - Related Model Numbers

3-26 Solo E1 DSU User Guide—June 19983

Seite 116 - Model Number Description

4-14Maintenance 4This chapter discusses maintenance methods for the Solo E1 DSU: ¥ ÒMenu-1 Main StatusÓ on page 4-2¥ ÒMenu-2 Data StatusÓ on page 4-5¥

Seite 117 - Assignments

4-2 Solo E1 DSU User Guide—June 19984If SNMP is enabled, SNMP TRAPs are sent as conÞgured in Menu-0 SNMP ConÞguration (see Figure 3-6 on page 3-16); o

Seite 118 - DATA port can

Maintenance 4-34Figure 4-1 Menu-1 Main StatusDuring testing, Menu-1 Main Status displays the test status. All parameters in Menu-1 are read-only. When

Seite 119 - DTE side connection only

viii Solo E1 DSU User Guide—June 1998 Chapter 5, Diagnostics 5-1 Diagnostic Considerations 5-1 Running A Diagnostic 5-1 Shortcut 5-2 Self Test 5-4 Th

Seite 120

4-4 Solo E1 DSU User Guide—June 19984Network StatusNetwork Status indicates any abnormal conditions present on the received E1 signal.DTE Loopback (fu

Seite 121 - RS-449 DB-25

Maintenance 4-54Error StatisticsDefaultÑNormal, default alarm status messages are displayed. User-deÞnedÑenter up to 20 characters to replace the norm

Seite 122 - Pin Signal Description

4-6 Solo E1 DSU User Guide—June 19984 Figure 4-2 Menu-2 Data DTE StatusDATA StatusData Status shows any abnormal conditions present on the received Da

Seite 123 - DE-9 DB-25

Maintenance 4-74¥ Event LogÑpresents a log of information during the past 24-hour period.Use the arrow keys to choose a menu and press the return key

Seite 124

4-8 Solo E1 DSU User Guide—June 19984Figure 4-4 Menu-3 Perf. Reports—Carrier Reg., Cur. IntervalTable 4-5 describes the parameters shown in Figure 4-4

Seite 125 - Factory Default ConÞgurationC

Maintenance 4-94Carrier Registers, Total over 24 HoursThe Menu-3 Performance Reports, Carrier Registers, Total Over 24 Hours menu selection is the sam

Seite 126 - Item Default Item Default

4-10 Solo E1 DSU User Guide—June 19984 Carrier Registers, 24-Hour DetailThe data is organized and displayed in 96 15-minute intervals. Performance dat

Seite 127 - ConÞguration Worksheet D

Maintenance 4-114User Registers, 24-Hour DetailPerformance data in the user registers for the last 24 hours is displayed in the User Registers, 24-hou

Seite 128 - Item Setting Item Setting

4-12 Solo E1 DSU User Guide—June 19984Figure 4-8 Menu-3 Performance Reports—Event LogTable 4-7 shows which status changes can be logged as events.Tabl

Seite 129 - Software Download E

Maintenance 4-134DTE Loss of Signal, Local TestNetwork Loss of Signal, Loss of Frame, UA1 Received, RAI Received, Set Code Received, Reset Code Receiv

Seite 130 - Setting Up for TFTP

Table of Contents ix Chapter 6, Troubleshooting 6-1 Appendix A, Technical SpeciÞcations A-1 Regulatory A-2 Diagnostics A-4 Telnet and SNMP Management

Seite 131 - Initiating TFTP

4-14 Solo E1 DSU User Guide—June 19984

Seite 132 - (as instructed in the

5-15Diagnostics 5This chapter explains using diagnostics to locate and resolve problems with the Solo E1 DSU and/or equipment connected to the Solo E1

Seite 133 - Group Field Description

5-2 Solo E1 DSU User Guide—June 19985Figure 5-1 Menu-9 DiagnosticsTable 5-1, Table 5-2, and Table 5-3 describe the Menu-9 Diagnostics parameters of Fi

Seite 134 - Abnormal Termination

Diagnostics 5-354. Type y for yes and the test will begin.The tests available in the Next Test parameter are shown in Table 5-2.Table 5-1 Meru-9 Diag

Seite 135 - Error Indicators

5-4 Solo E1 DSU User Guide—June 19985Self TestThe Self Test checks the DSU/CSU electronic components and performs a signal path check of transmit and

Seite 136 - Download Aborted by User

Diagnostics 5-55Possible messages are RUNNING SELF TEST, SELF TEST PASSED or ERROR <N>, where <N> is one of the error codes shown in Table

Seite 137

5-6 Solo E1 DSU User Guide—June 19985The Loop DTE TestThe Loop DTE test veriÞes the operation of the DSU/CSU and the associated DTE cabling and equipm

Seite 138

Diagnostics 5-75Alternate OptionThe signal sent is exactly opposite the signal sent in standard mode. This is useful for testing a remote unit that ha

Seite 139 - Index I-3

5-8 Solo E1 DSU User Guide—June 19985It loops the payload data received from the E1 network back toward the network. Before it is looped back, the dat

Seite 140

Diagnostics 5-95The Loopup/Down Remote TestsThe loopup remote test puts the remote DSU/CSU into network loopback. Once in loopup remote, test patterns